CEÈÏÖ¤SAR²âÊÔ¸ÅÊö
SAR²âÊÔÊÇÖ¸µç´Å²¨ÎüÊÕ±ÈÖµ»ò±ÈÎüÊÕÂÊ£¬£¬£¬£¬£¬ÔÚCEÈÏÖ¤Öбê×¼½ÓÄÉÏÞÖµ±ê×¼
EN 50360-2001 Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields(300 MHz ¨C 3 GHz)²úÆ·±ê×¼
EN 50566©\2013 Product standard to demonstrate compliance of radio frequency fields from hand held and body-mounted wireless communication devices used by the general public (30 MHz -- 6 GHz)ÊÖÒÕ±ê×¼
EN 62209-1-2006 Human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices ¡ª Human models, instrumentation, and procedures ¡ªPart 1: Procedure to determine the specific absorption rate (SAR) for hand-held devices used in close proximity to the ear (frequency range of 300 MHz to 3 GHz)
EN 62209-2-2010 Human exposure to radiofrequency fields from hand-held and body mounted wireless communication devices ¡ª Human models, instrumentation, and procedures Part 2: Procedure to determine the specific absorption rate (SAR) for wireless communication devices used in close proximity to the human body(frequency range of 30 MHz to 6 GHz)
EN 62479-2010 Assessment of the compliance of low power electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (10 MHz - 300 GHz)
ÆäÖУ¬£¬£¬£¬£¬ÊÖÒÕ±ê×¼EN 62209-2-2010×÷Ϊ²úÆ·±ê×¼EN 50566©\2013µÄÊÖÒչ淶ÐÔÎļþ£¬£¬£¬£¬£¬½ç˵body SAR¼ì²â¾àÀ룬£¬£¬£¬£¬ÓɲúÆ·ÖÆÔìÉÌÆ¾Ö¤½ç˵Æä²úÆ·Ô¤ÆÚʹÓõĵ䷶¾àÀë¡£¡£¡£¡£ÈçÊÖ»úÀ࣬£¬£¬£¬£¬ body SAR¿É½ç˵²¢½ÓÄÉ10 mm/ 15 mm×÷ΪÆÀ¹À¾àÀë¡£¡£¡£¡£
±ê×¼ÖØ´ó±ä»»
2014Ä꣬£¬£¬£¬£¬·¨¹ú¶Ô±ê×¼EN 50566©\2013Ìá³öÒìÒ飬£¬£¬£¬£¬Ö¸³öӦ˼Á¿±ãЯºÍÒÆ¶¯Ê½²úÆ·µÄÏêϸʹÓÃÌõ¼þ£¬£¬£¬£¬£¬²¢Ó¦Ìá³öbody SAR µÄÆÀ¹À¾àÀë¡£¡£¡£¡£Å·Ã˾ÓÉÆÀ¹ÀºóÒÔΪ¸ÃÌáÒéºÏÀí£¬£¬£¬£¬£¬Ðè¶ÔEN50566¾ÙÐÐÐÞ¶©Ôö²¹£¬£¬£¬£¬£¬ÄÚÈÝÈçÏ£º
¾¯Ê¾:»ùÓÚÇå¾²ÐÔÄ¿µÄ,Á¬ÏµÖ¸Áî1999/5/ECµÄArticle 3(1)(a)Ìõ¿îÒÔ¼°¸½¼þI ÖÁÖ¸Áî2006/95/ EC£¬£¬£¬£¬£¬»®¶¨ÔÚʹÓô˲âÊÔ±ê׼ʱӦÇкÏÏà¹Ø¾àÀë¾àÀëµÄ»®¶¨£¬£¬£¬£¬£¬²¢ÄÜ·´Ó¦³ö×°±¸ÏÖʵһÑùƽ³£Ê¹ÓÃʱµÄÕæÕæÏàÐΣ¬£¬£¬£¬£¬È·±£¹«ÖÚÔÚʹÓã¨30MHz£6GHz£©ÊÖ³ÖʽºÍÉíÌåÅå´øÊ½ÎÞÏßͨѶװ±¸Ê±µÄÇå¾²ÐÔ¡£¡£¡£¡£ ¾ÙÀý˵Ã÷£¬£¬£¬£¬£¬¹ØÓÚÖ«ÌåSARÆÀ¹À£¨ÏÞֵΪ4W/kg£©£¬£¬£¬£¬£¬ÕÉÁ¿¾àÀë¾àÀëΪ0£¨×°±¸Ö±½Ó½Ó´¥Ä£×Ó£©£»£»£»£»£»£»¹ØÓÚÉíÌåbody SAR£¨ÏÞֵΪ2W/kg£©£¬£¬£¬£¬£¬ÕÉÁ¿¾àÀë¾àÀë¿ÉÒÔÊǼ¸mm¡£¡£¡£¡£ ¡¾Warning: The application of this publication shall observe certain conditions relating to the separation distance, reflecting the practical day to day use, ensuring the safe use of handheld and body©\mounted wireless communication devices used by the general public (30 MHz ©\ 6 GHz), for the purposes of the safety objectives provided for in Article 3 (1) (a) of Directive 1999/5/EC, in conjunction with Annex I to Directive 2006/95/EC. For example, for limb SAR measurements (limit 4 W/kg), no separation distance may be used (device in contact); for trunk SAR measurements (limit 2 W/kg) a separation distance of less than a few millimetres may be used.¡¿
¾ÝϤ£¬£¬£¬£¬£¬Å·Ã˽«ºÜ¿ÉÄÜÔÚ½üÆÚ£¬£¬£¬£¬£¬¼´2016ÄêÖУ¬£¬£¬£¬£¬ÍÆÐУºÖ«ÌåSARÕÉÁ¿£¨ÏÞֵΪ4W/kg£©£¬£¬£¬£¬£¬ÕÉÁ¿¾àÀë¾àÀëΪ0£»£»£»£»£»£»body SAR£¨ÏÞֵΪ2W/kg£©£¬£¬£¬£¬£¬ÕÉÁ¿¾àÀë¾àÀëΪ5mm¡£¡£¡£¡£Òò´Ë£¬£¬£¬£¬£¬¹ØÓÚ½üÆÚÍýÏ뿪չŷÃËSAR¼ì²âµÄÏîÄ¿ÁÐλÈÏÕæÈË£¬£¬£¬£¬£¬Í¬Ò«ÊµÑéÊÒÌØÊâÌáÐÑ£ºÇëÌáǰ×Ðϸ×öºÃÑз¢ÆÀ¹À£¬£¬£¬£¬£¬×èÖ¹ÔÚÈÏ֤ʱ·ºÆðfail£¬£¬£¬£¬£¬¶øÊ¹Õû¸öÈÏÖ¤ÖÜÆÚÁè¼Ý¿ØÖƹæÄ£¡£¡£¡£¡£
ÒÔÏÂÊÇʵÑéÊÒ»®·ÖÑéÖ¤15mm/10mm/5mm/0mm Body SARËù»ñµÃµÄÒ»×éÊý¾Ý£¬£¬£¬£¬£¬¹©²Î¿¼¡£¡£¡£¡£